A Bowie-Dick test is used in pre-vacuum type (or dynamic air removal) sterilizers. They are used to detect air leaks and inadequate air
removal and consist of folded 100% cotton surgical towels that are clean and preconditioned. A commercially available Bowie-Dick-type
test sheet should be placed in the center of the pack.
The test pack should be placed horizontally in the front, bottom section of the sterilizer rack, near the door and over the drain, in an
otherwise empty chamber and run at 134°C for 3.5 minutes. The test is used each day the vacuum-type steam sterilizer is used, before
the first processed load.
Air that is not removed from the chamber will interfere with steam contact. Smaller, commercially available disposable test packs (or
process challenge devices) have been devised to replace the stack of folded surgical towels for testing the efficacy of the vacuum
system in a pre vacuum sterilizer.
They should be representative of the load and simulate the greatest challenge to the load. Sterilizer vacuum performance is acceptable
if the sheet inside the test pack shows a uniform color change. Entrapped air will cause a spot to appear on the test sheet, due to the
inability of the steam to reach the chemical indicator. If the sterilizer fails the Bowie-Dick test, do not use the sterilizer until it is
inspected by the sterilizer maintenance personnel and passes the Bowie-Dick test.
Autoclave Test Sheet _Bowie Dick Test Sheet 1’s (Moq)
R8,50
Autoclave Test Sheet _Bowie Dick Test Sheet 1’s (Moq)
Be the first to review “Autoclave Test Sheet _Bowie Dick Test Sheet 1’s (Moq)” Cancel reply
Related products
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R24 840,00
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R250,00
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R895,00
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R495,00

Hospital Standard Bed, complete with mattress (swivel castors optional)
Otoscope Conventional Deluxe (full Set)
Chair Bed (Accompany Chair)
Shopper Tricycle Steel ,front basket
Hospital Stretcher Gas spring Backrest, Trendelenburg and reverse, O2 cylinder Holder
Ultrasound Gel 100ml, 1’s -Moq
Walking Pulpit Frame Non-Foldable, sizes Small, Medium, Large
Gauze Dressing Chlorhexidine impregnated 10x10, Box 10's
Fetal Doppler BF600+, 2Mhz portable with up 4hrs Battery operation
Three-seater chair for waiting room - 150kg per seat
Shower or Bath Grab Bar 1’s
Capnograph Handheld model CA10S
Surgical carbon Steel Sterile complete( Scalpel complete)- Assorted sizes 10’s-pack
Blood Pressure Cuff and Bladder Adult dual tube, Cotton
Surgical Tray Dressing Large
ECG Record Paper for Welch Allyn ELI150
Fetal Monitoring CMS800G _ Twin probe only
Biotain 0.5% chlorhexidine and 70% alcohol, 1L
Blood Pressure Aneroid single-handed with shatterproof gauge
Autoclave BKM-P18III Portable 








Reviews
There are no reviews yet.