A Bowie-Dick test is used in pre-vacuum type (or dynamic air removal) sterilizers. They are used to detect air leaks and inadequate air
removal and consist of folded 100% cotton surgical towels that are clean and preconditioned. A commercially available Bowie-Dick-type
test sheet should be placed in the center of the pack.
The test pack should be placed horizontally in the front, bottom section of the sterilizer rack, near the door and over the drain, in an
otherwise empty chamber and run at 134°C for 3.5 minutes. The test is used each day the vacuum-type steam sterilizer is used, before
the first processed load.
Air that is not removed from the chamber will interfere with steam contact. Smaller, commercially available disposable test packs (or
process challenge devices) have been devised to replace the stack of folded surgical towels for testing the efficacy of the vacuum
system in a pre vacuum sterilizer.
They should be representative of the load and simulate the greatest challenge to the load. Sterilizer vacuum performance is acceptable
if the sheet inside the test pack shows a uniform color change. Entrapped air will cause a spot to appear on the test sheet, due to the
inability of the steam to reach the chemical indicator. If the sterilizer fails the Bowie-Dick test, do not use the sterilizer until it is
inspected by the sterilizer maintenance personnel and passes the Bowie-Dick test.
Autoclave Test Sheet _Bowie Dick Test Sheet 1’s (Moq)
R8,50
Autoclave Test Sheet _Bowie Dick Test Sheet 1’s (Moq)
Be the first to review “Autoclave Test Sheet _Bowie Dick Test Sheet 1’s (Moq)” Cancel reply
Related products
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R495,00
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R31 895,07
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R24 840,00
Sterilization/ Autoclaves, UV Sterilizers, Disinfectants & more
R1 450,00

Feeding Pump KL5021A (Enteral)
Shopper Quad Aluminum Front Basket
Bed Screen 3-fold
Defibrillator Life7, Paramedic series, Pacemaker & NiBp/Spo2, 5-Lead Cable, Printer (Free case valued R3,200))
Autoclave 16L Table top with Micro-processor Control (Class2)
EEG Brain mapping machine _ Disk Leads only
Diagnostic Set universal Economy
ECG 5-Lead cable
Diathermy _ Handle and Finger-switch Re-use
Surgical Skin Marker fine or regular tip(Sterile)
Cotton Balls 500g pack ( Non-sterile)
ECG Record Paper for Philips M2483A
Antiseptic Solution 50ml HI Care 1’s (Moq )
Diathermy _ Monopolar Electrode, Ball, Blade or Needle shaped , 1’s- Moq
Commode with Castors Lock and detachable Arm / Footrest
ECG Cable 10-Lead with button connectors
AED CU-SP1 _ Pads adult only
Ice pack 22cm 1’s (Moq)
Defibrillator Life7 _ Carry case only
SP02-TOP26 AED Rescue Sam, Carry case optional (Public access Defibrillator)
Space Blanket Adult or Child 1’s (moq)
Veterinary Oximeter model CMS60D-Vet
Doppler Vascular 8Mhz probe Sonoline C
EEG Brain mapping machine
Simulator CPR (Little Ann Manikin)
Alcohol Swab box 200’s dim 65x28mm
Toilet Raiser Seat
Shopper Quad Aluminum Front Basket
ECG Record Paper for Doppler CMS800G
Gauze Dressing Chlorhexidine impregnated 10x10, Box 10's
ECG D-HEART Monitoring for professionals & Non-professionals
Simulator IV Training arm
ECG Machine 12-Lead 8”inch Screen with Interpretation _ Paper only 








Reviews
There are no reviews yet.