1-MODEL: PULSE OXIMETER FINGERTIP CMS-50D
FEATURES:
• Integrated with SPO2 Probe and processing display
module
• High accuracy and durability
• Can be used in Hospital, home, community medical
treatment, sports – healthcare, etc
• Can Measure SPO2 and Pulse Rate accurately
• SPO2 and Pulse Rate Display, Pulse rate waveform and
bar graph display
• Battery voltage low indication
• Four directions and 6 modes
• Four levels adjustable brightness
• Low power consumption
• Automatic Power off Function – display format can be
saved after power off
DIMENSIONS: 57MM (L) X 31MM (W) X 32mm (H)
DISPLAY FORMAT:1.3” double colour OLED Display, resolution 160 x 64
SPO2: 35 – 99% Pulse Ratio – 30~250BPM
RESOLUTION:1% For SPO2, 1 BPM for Pulse Ratio
ACCURACY:(2%)70 – 99% Unspecified (<70%) for SPO2, 2BPM OR 2% (select larger) for pulse ratio
Battery Voltage: DC2.6V – 3.6V
POWER SUPPLY: 1.5V (AAA ) size alkaline batteries x 2
CONTINUOUS USE: > 30 HOURS
INTERFERENCE RESISTANCE CAPACITY AGAINST AMBIENTLIGHT AND MEASUREMENT PERFORMANCE AT LOW PERFUSION
QUALITY APPROVAL :CE
2-MODEL CMS50DL
Basically function:
- Display Sp02,PR saturation value;
- Pulse rate and Puise rate Bargraph;
- Battery-low indicator;
- The Oximeter can be powered off automatic ;
Technical specifications
- Sp02 Measuring Range: 0% -100%;
- Pulse Rate Measuring Range: 30 bpm – 250 bpm;
Measurement Accuracy: ±2% in stage of 70%-100% Sp02, and meaningless when stage being smaller than 70%.±2 bpm or±2% (select larger) for Pulse Rate
Resolution: 1% for Sp02 and 1 bpm for Pulse Rate.
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Measurement Performance in Weak Filling Condition: Sp02 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. Sp02 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Power Consumption: Smaller than 25 mA.
Power Requirements: 2 xl.5V AAA alkaline battery (or using the rechargeable battery instead , adaptable range: 2.6V—3.6V.

Antiseptic Solution 50ML or 100ML Hi-Care, 1’s (Moq)
ECG Machine 12-Lead 10”inch Screen with Interpretation
ECG Record Paper for Welch Allyn CP100
Simulator IV Training arm
Blood Pressure Meter Aneroid Wall Mount Square swivel
Tray instruments with Cover 305 x 205 x 50mm
Examination Lamp mobile Economy
AED CU-SP1 _ Pads Pediatric only
ECG Machine, 3-Channel with Interpretation (Ecg300)
Cold Sterilant Washer Endozime 4L
Laryngoscope 4-Blades Set, conventional in white case
ECG Cable 10-Lead for Portable Holter system model TLC5000
Spirometer SP10 
























Reviews
There are no reviews yet.