MODEL: PATIENT MONITOR CONTEC MODEL CMS9000-PR/NiBp/SpO2/Temp/ECG
FEATURES:
■ 12.1” Screen, Colour TFT Screen, waveform up to 8 channels
■ Light and portable with build-in rechargeable battery
■ UP to 10 kinds of monitor parameters
■ Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
■ 72 hour storage and review of trend grams and tables, 40 second review of olographic
waveforms. No USB port.
■ Built-in recorder (option)
■ All-round monitor of adult, pediatric and neonatal.
■ Electrosurgical unit and defibrillation protected
MODEL: CMS9000
Display Colour TFT Screen
NIBP:
-Method:Oscillometry
-Operation Modes: Manual/Automatic/STAT
-Measurement unit: mmGh/kPa selectable
-Measurement Types: Systolic, Diastolic, Mean
-Measurement range: Adult 10 – 270mmHG
-Overpressure protection: YES
-Resolution:1mmHg
-Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
-Alarm: Systolic, Diastolic, Mean
SP02
Measurement range: 0-100%
Accuracy:±2 digit (70~100%) 0 ~69% unspecified
Alarm range: 0-100%
ECG
Input: 5-lead or 3-lead selectable
Lead Selection: 5-lead: RA, LA, RL, LL, V or R, L, N, F, C
Gain selection: I, II, III, avr, avl, avf, vx, CAL 12.5mm/s, 25mm/s, 50mm/s
Accuracy: ±1bpm or ±1%, whichever is greater
Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
Calibration Signal:1mV±5%
Operation modes: Dianostic, Monitor, Surgery
Alarm Range: 15-300bpm
Peadiatric/Neonatal: 15-350bpm
Alarm range:-2.0mV~2.0mV
S-T detection: Yes, Arrhythmia analysis: YES
Alarm: Yes, audible and visual alarm, alarm events recallable
RESPIRATION
Method:RA-LL impedance
Peadiatric/Neonatal: 6-150rpm
Alarm range: 6-120rpm
Peadiatric/Neonatal:6-150rpm
Apnea Alarm: YES
TEMPERATURE
Resolution: 0.1°C
Channel: Dual-channel
Alarm range: 0-50°C
Option:
ETCO2
Measurement Mode: Side-stream or mainstream
Measurement range: EtC02: 0-99mmHg
Accuracy:CO2 concentration
Apnea alarm: YES
CO
Method:CO: 0.1-20Lit./min
Measurement range: Thermo-dilution
IBP
Channel: 2 channels
Pressure transducer: Sensitivity: 5 (mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range:10~300mmHG
–

Hospital Bed 1-Function complete with mattress, IV Pole Side rails, ABS boards
Pressure Mattress Stage one and two
Bioscrub 500ml without pump Hand wash
ECG Record Paper for Welch Allyn ELI150
Nitrocare Stretcher, Trendelenburg, Oxygen cylinder Holder(No X-RAY)
Disinfectant _ Hand sanitizer Spray 60ml (Moq) 